5.

MOD. RSU-231, AC 110/230V, Current: 1.05/0.53A, Power consumption: 88W, Plug type: , Portable Suction Unit, HS CODE: 901890, UNCCS CODE: 481698, UNSPSC CODE: 42142400, UMDNS CODE: 10208, GMDN CODE: 36777, Main construction: Cast aluminium and ABS, Plastic bottle: 1pc x 1,000c.c. graduated at 50c.c. autoclavable at 130°C plastic bottle with silicone rubber seal, Max. suction: 0~-65/-70 cm/Hg, Select valve: No, Vacuum control: Needle valve, Vacuum indicator: 0~-76 cm/Hg graduated at 5 cm/Hg Bourdon tube type gauge, Vacuum flow: 0~35 liter/min, Max. HP: 88W 1/8HP, Safety device: Water stop device, disposable bacterial filter >99.999% (0.3 micron) and no fuse breaker, Extra function: No, Foot control: No, Noise: 50 dB, Pump: Oil-less twin piston pump with overload protection, Cooling fan: No, W/S: suction tube 180cm x 1pc, suction catheter x 1pc, filter (small) x 2pcs
HS CODE: 901890
UNCCS CODE: 481698
UNSPSC CODE: 42142400
UMDNS CODE: 10208
GMDN CODE: 36777

Intended For Use: Devices that are used to evacuate gas, fluid, tissue, or other foreign materials from a body cavity by means of suction. They generally consist of a motorized suction pump (some hospitals have a central vacuum system), rubber tubing, a plastic/glass specimen container, a pressure gauge, a vacuum control adjustment knob, and sometimes, a microbial filter. The pump creates a vacuum in the suction tubing, which is inserted into the cavity for the removal of gases, fluids, or other particles, which are removed and routed to the specimen container. Aspirators may also consist only of a simple rubber bulb and pipette that is inserted into the cavity and manually squeezed to remove the fluid, gas, or other material. Typically, these devices are used by surgeons, assisting surgeons, or nurses during surgery, but they may also be used at the bedside, in the home, in long-term nursing home facilities, and during emergency medical response.
Specifications
ModelRSU-231
Power supplyAC 110/230V
Current1.05/0.53A
Power consumption88W
Plug type
TypePortable Suction Unit
HS CODE901890
UNCCS CODE481698
UNSPSC CODE42142400
UMDNS CODE10208
GMDN CODE36777
Main constructionCast aluminium and ABS
Plastic bottle1pc x 1,000c.c. graduated at 50c.c. autoclavable at 130°C plastic bottle with silicone rubber seal
Max. suction0~-65/-70 cm/Hg
Select valveNo
Vacuum controlNeedle valve
Vacuum indicator0~-76 cm/Hg graduated at 5 cm/Hg Bourdon tube type gauge
Vacuum flow0~35 liter/min
Max. HP88W 1/8HP
Safety deviceWater stop device, disposable bacterial filter >99.999% (0.3 micron) and no fuse breaker
Extra functionNo
Foot controlNo
Noise50 dB
PumpOil-less twin piston pump with overload protection
Cooling fanNo


Standard Accessories Suction tube 180cm x 1pc
Suction catheter x 1pc
Filter (small) x 2pcs


Optional Accessories RAC-SU001, 1,000c.c. Bottle x 1set
RAC-SU002, Filter (S) x 1pc
RAC-SU006, Filter (L) x 1pc
RAC-SU010, Water stop device x 1pc
RAC-SU013, Suction cannula tube x 1set


Production
Capability50 units
Lead time30 days


Shipping Information
N.W.6.3 KGS
G.W.7 KGS
Machine size (LxWxH)cm42x16x28
Carton box (LxWxH)cm50x23x35
Wooden case (LxWxH)cm65x38x50
V.W.21 KGS
CBM0.124
CUFT4.361
20'DC540 units
40'DC1,134 units
40'HQ1,134 units


Certificate
EU / Class / RuleCE0434, Class IIa, 11
FDA / Code / Class878.4780, JCX, Class II, 510(K)
TFDA / ClassI-4780, Class II, GMP